Technical

Composite Panel Refurbishment Guide

Technical guidance for building owners and surveyors on assessing and refurbishing insulated composite cladding panel systems.

8 min read

Key Decision Points
  • Composite panels can be refurbished where the outer skin is sound and joints are performing adequately.
  • Joint integrity assessment is a prerequisite — coating the outer skin over failed joints does not resolve water ingress.
  • Insulation condition must be checked: waterlogged insulation cores may require panel replacement regardless of outer skin condition.
  • Steel-skinned composite panels use the same coating approach as profiled steel — ProFix for cut edges, then top coat.
  • Panel classification matters for buildings subject to fire safety review — coating does not change fire performance classification.

What Are Composite Cladding Panels?

Composite insulated cladding panels consist of two outer metal skins (typically steel, sometimes aluminium) bonded to an insulation core (PIR, mineral wool, or EPS depending on generation and specification). They are extensively used on commercial and industrial buildings for their thermal performance, fast installation, and clean appearance. Common systems include secret fix panels with concealed joints, through-fix panels, and micro-rib or flat-faced profiles for commercial and retail applications.

For refurbishment purposes, the key characteristics are: the outer skin material (determines primer and coating system); the joint type (determines what joint maintenance is required alongside the coating programme); the insulation type (affects fire compliance status); and the installation generation (older panels may have different joint specifications and known failure modes).

Why Composite Panels Deteriorate

The outer skin coating degrades through the same UV, moisture and atmospheric mechanisms as profiled steel — fading, chalking, and eventually coating failure. However, composite panels have additional deterioration modes specific to their construction: joint sealant failure between panels; joint capsule or jointing compound failure on through-fixed systems; and, in older panels, potential loss of bond between the outer skin and the insulation core (delamination).

On steel-skinned panels, cut edges at panel ends, openings, and penetrations are susceptible to the same edge corrosion risk as profiled steel sheets. The edge profile on composite panels is typically smaller than on profiled roofing — but the corrosion mechanism is identical and requires the same treatment approach.

How Is Condition Assessed?

Assessment covers four areas: outer skin condition (coating adhesion, chalking extent, surface corrosion); joint condition (sealant integrity, whether joints are open, cracked or weathered through); fixings condition (for through-fixed systems, fixing head condition and whether corrosion is occurring at fixing points); and, where any doubt exists about internal panel condition, a moisture meter survey or thermal imaging to identify waterlogged insulation sections.

When Refurbishment May Be Suitable

Composite panel refurbishment is appropriate where: the outer skin is structurally sound (no delamination from core, no perforation); the existing coating can be adequately prepared for over-coating; joints can be renewed or have been maintained; and there are no fire safety compliance requirements that mandate panel replacement. The coating programme for composite panels follows the same sequence as for profiled steel — preparation, cut edge treatment where required, then spray-applied top coat.

When Refurbishment May Not Be Suitable

Coating the outer skin of a composite panel system with failed joints and waterlogged insulation does not address the underlying water penetration problem. The coating will fail from behind as moisture migration continues through the panel system.

Panel replacement is required where: outer skin delamination from the insulation core has occurred; insulation has become waterlogged and is retaining moisture (identifiable by moisture meter or thermal imaging); cut edges have perforated; or where fire safety compliance requirements mandate removal and replacement with a classified system.

Fire Safety Considerations

Composite insulated panels using PIR or EPS foam cores have been subject to significant regulatory attention following the Grenfell Tower fire. Buildings within scope of the Building Safety Act 2022 — broadly, residential buildings over 11m but also applicable to certain non-residential buildings — should obtain fire safety advice before proceeding with any works to the cladding system. Spray-applied coating does not change the fire classification of the panel system beneath it.

What Affects Cost?

In addition to the standard drivers (area, access, preparation), composite panel projects carry cost factors specific to the panel type: joint renewal (measured per linear metre of joint requiring resealing); fixing head treatment or replacement where corrosion is present; and any thermal imaging or moisture survey required before specification can be finalised. Secret-fix panel systems have different access requirements at joints compared to through-fixed systems.

What Affects Lifespan?

Coating performance on composite panels depends on outer skin preparation and system compatibility, as for profiled steel. However, the joint system is an independent lifespan variable — a well-coated outer skin with failed joints will allow water penetration that undermines the whole panel system from within. Joint renewal is not optional on composite panel buildings where the joint sealant is at or beyond its service life.

Forti Nova Assessment

Composite panel refurbishment is frequently straightforward where the building is relatively modern and the panels are in good physical condition — the coating is the only element requiring attention. The cases that require more care are older buildings from the 1990s and early 2000s, where joint compounds and original sealants have reached the end of their service life, where thermal bridging through the original panel connections may have led to condensation and insulation saturation, and where the fire classification of the panel construction is now under scrutiny.

Our recommendation is always to carry out a joint survey and, on any building over 15 years old, a moisture meter survey of the insulation before finalising the refurbishment scope. The cost of missing waterlogged panels in the specification — and having to revisit them after the outer coating has been applied — is much higher than the cost of identifying them at assessment stage.

Common Mistakes

  • Coating the outer skin without assessing or renewing the joint sealant system.
  • Not checking insulation condition for moisture ingress before proceeding with refurbishment.
  • Assuming fire safety compliance is unchanged because the panel cladding type looks unchanged — classification depends on the complete system, not just the outer skin.
  • Using a standard steel primer on aluminium-skinned composite panels.

Frequently Asked Questions

Can secret-fix composite panels be refurbished?

Yes. Secret-fix panels can be over-coated using the same spray-applied approach as through-fix systems. Joint access for sealant renewal may be more complex on secret-fix systems — this affects the programme but not the technical feasibility of refurbishment.

Do I need to renew the joints when I refurbish the outer skin?

This depends on joint condition. Joints that are performing adequately do not need renewal. Joints that show cracking, separation or degradation should be renewed as part of the programme — coating the outer skin without addressing failed joints will not prevent water ingress.

Is it safe to refurbish PIR-core composite panels?

Spray-applied refurbishment of the outer coating on composite panels does not affect the fire performance of the panel system. However, any building subject to fire safety review under current regulations should seek specialist fire safety advice before proceeding with any work to the cladding system.

How long will composite panel refurbishment last?

Service life depends on outer skin preparation, system selection and atmospheric exposure — the same variables as for profiled steel. Joint renewal, where incorporated, has its own service life (typically 10–15 years for modern sealant systems). Both elements of the refurbishment should be on the same maintenance inspection programme.

Request a Site Assessment

Every refurbishment decision should be grounded in a site-specific assessment. Submit your building details and an approved applicator will confirm what your building needs.

Start Assessment